## Overnight test results
An overnight test was conducted with 2 Thingy:52 nodes placed in two separate
rooms (windows closed, 7h session, 5 minute interval).
- Room 1: 4 occupants (2 adults, 2 children)
- Room 2: unoccupied
![Overnight measurements](mesures_nuit.png)
CO2 rose progressively from 400 ppm to a peak of 1071 ppm in the occupied room,
consistent with human respiration in a confined space. The unoccupied room
remained stable between 400 and 465 ppm, confirming that variations in Room 1
are directly linked to human presence.
Note: the CCS811 sensor measures eCO2 estimated from VOC levels, not direct CO2.
Occasional spikes (e.g. 877 ppm at 02:45, 1071 ppm at 03:05) may be caused by
factors such as perspiration or movement near the sensor and should be interpreted
with caution.